Safety Alert
Blow Out Preventer (BOP) Drops to Seabed
Read at IADCOpens the publisher’s page on iadc.org
Summary
This alert describes a blowout preventer falling to the seabed during deployment on marine riser. A subsea engineer inadvertently triggered the emergency disconnect sequence after mistaking its button for the wellhead connector valve override, separating the preventer from the lower marine riser package.