Investigation Report
Inadvertent Blind Shear Ram Activation During Casing Pressure Test Preparations
Read at BSEEOpens the document on bsee.gov
Summary
An investigation examines inadvertent blind shear ram activation during preparations for a casing pressure test. A sheared drill-pipe joint dropped 500 feet into the wellbore, without personnel injury. The report discusses control protection, human error and possible lack of experience, alongside planned procedural changes involving two competent people and verbal confirmation.