Investigation Report

Fire on Unmanned Platform Following Release onto Reboiler

BSEEBureau of Safety and Environmental Enforcement

06-30-2005 12:05 G25601 HI/A287 Fire

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a fire on the unmanned HI A-287 platform. Suspected vibration-related tubing fitting failure released condensate, glycol and gas onto a reboiler. The report describes renewed burning, valve failures and damaged extinguisher hoses, and recommends an alert advocating hard piping and additional bracing.

Topics

About This Record
Original title
06-30-2005 12:05 G25601 HI/A287 Fire
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Hydrocarbon Release, Mechanical Failure
Equipment
Hose, Process Pipework and Pipelines, Pumps, Valve
Control
Fire Protection, Energy and Process Isolation
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working