Summary
Investigation of accidental drill-pipe shearing on H&P 203 while setting a test plug. A shear-ram contact switch was stuck closed, allowing the rams to fire when the operating button was pressed. The report identifies absent warning provision and records a subsequent control-logic change to flash an indicator for stuck switches.
Classifications: Mechanical failure; equipment failure.
Classifications: Drilling; well drilling.
Classifications: Blowout preventer; BOP; blow-out preventer.
Classifications: Operator displays and control interfaces.
Classifications: Alarm management.