Safety Flash
Crane wire failure
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A crane wire parted during night-time recovery of a work-class ROV onto a survey vessel. The investigation linked prior over-recovery to sheave damage and crushed wire, followed by impact loading through the splash zone. Corrective actions addressed inspection checklists, reporting findings, management of change and risk assessments.