Investigation Report

BOP Test Stump Fell Overboard During LMRP–BOP Connection Leak Testing

BSEEBureau of Safety and Environmental Enforcement

03-09-2009 11:14 G23000 GC/847 Other - Item Lost Overboard

Read at BSEEOpens the document on bsee.gov

Summary

An investigation records a BOP test stump falling overboard during leak testing of the LMRP–BOP connection above the moon pool. Inadvertent activation released the stump. The report identifies unrecognised management-of-change needs and absent lockout/tagout, and records planned procedural changes. No damage or pollution resulted; the stump could not be recovered.

Topics

About This Record
Original title
03-09-2009 11:14 G23000 GC/847 Other - Item Lost Overboard
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects
Activity
Drilling, Pressure Testing
Equipment
Blowout Preventer
Control
Lockout and Tagout, Management of Change, Operating and Work Procedures
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-e6595b3ac4 · added 2 October 2026