Investigation Report

Gas Release Following Sand Damage to Well Equipment

BSEEBureau of Safety and Environmental Enforcement

10-06-2010 13:00 G02391 HI A 571 Damage >25K

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of sand damage and a subsequent gas release from well A-15 at HI-A571. Sand damaged the choke and pressure-relief discharge piping, blocked pressure-sensing lines and impeded safety-valve closure. Manual wing-valve closure stopped the leak. Investigators also found a gas-detection shutdown relay bypassed and identified inadequate monitoring for continued sand production.

Topics

About This Record
Original title
10-06-2010 13:00 G02391 HI A 571 Damage >25K
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Functional Safety, Hydrocarbon Release, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Gas Detector, Process Pipework and Pipelines, Valve
Control
Pressure Relief
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-cfa65421bf · added 2 October 2026

Report a problem with this record