Investigation Report

High-Pressure Gas Release Following Transmitter Replacement

BSEEBureau of Safety and Environmental Enforcement

05-08-2018 09:15 RUE #: 23579 GC 787 A (Atlantis) Gas Release

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a high-pressure gas release on Atlantis following installation of unsuitable Teflon seals during transmitter replacement. Findings address contractor oversight, procedural knowledge, training and safety culture. Buyback gas prolonged the release, while bypassed shutdown functions and poorly positioned detectors undermined detection and emergency response.

Topics

About This Record
Original title
05-08-2018 09:15 RUE #: 23579 GC 787 A (Atlantis) Gas Release
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Functional Safety, Hydrocarbon Release, Leadership and Safety Culture, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Gas Detector, Valve
Control
Competence and Training, Contractor Management, Emergency Response, Operating and Work Procedures
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-a173db4d7a · added 2 October 2026

Report a problem with this record