Investigation Report

Leaking Glycol Ignited on Hot Compressor Exhaust Piping

BSEEBureau of Safety and Environmental Enforcement

05-24-2026 1138 G01315 MP 298 Fire

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a fire at Cantium’s Main Pass 298 A production platform. Glycol escaping from a pump hose connection passed through corrosion pinholes in containment decking and ignited on hot compressor exhaust piping. The report examines fitting security, containment deficiencies and firefighting actions; no injuries or pollution were reported.

Topics

About This Record
Original title
05-24-2026 1138 G01315 MP 298 Fire
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Corrosion, Fire, Loss of Containment, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Hose, Pumps
Control
Fire Protection
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-6469a10916 · added 2 October 2026

Report a problem with this record