Investigation Report

Flash Fire During Coiled Tubing Operations

BSEEBureau of Safety and Environmental Enforcement

10-02-2010 07:00 G08641 EC/83 Required Evacuation - Fire - Other

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a flash fire during coiled tubing operations beside a producing platform. Gas venting through an open gas-buster clean-out valve migrated to a diesel pump engine and ignited following a backfire, burning the operator. Findings address missing fluid returns, inadequate hazard analysis, delayed simultaneous-operations planning and obstructed emergency egress.

Topics

About This Record
Original title
10-02-2010 07:00 G08641 EC/83 Required Evacuation - Fire - Other
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Human Factors, Hydrocarbon Release
Activity
Well Intervention
Equipment
Process Pipework and Pipelines, Pumps, Valve
Control
Ignition Source Control, Job Safety Analysis, Simultaneous Operations Coordination, Stop-Work Authority
Sector
Upstream Oil and Gas
Setting
Vessel
Link
Checked , working
Record
bsee-4d4f278c1a · added 2 October 2026