Investigation Report

Ejected Wireline Tool String Struck Worker During Well Abandonment

BSEEBureau of Safety and Environmental Enforcement

09-28-2011 08:15 00064 SS/114 LTA (>3 days) - Other

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of an injury during well abandonment when a wireline tool string and night cap were ejected approximately 100 feet into the air. The tool string struck a worker. Findings identify unrecognised trapped pressure and deficiencies in management of change, stop-work intervention and job safety analysis.

Topics

About This Record
Original title
09-28-2011 08:15 00064 SS/114 LTA (>3 days) - Other
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Line of Fire, Pressure Systems
Activity
Well Abandonment
Equipment
Hand Tools, Valve, Wellhead
Control
Energy and Process Isolation, Job Safety Analysis, Management of Change, Stop-Work Authority
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-327dacb1e8 · added 2 October 2026

Report a problem with this record