Investigation Report

Crane-Cab Fire Following Electrical Wiring Sparks

BSEEBureau of Safety and Environmental Enforcement

03-25-2014 22:00 00367 WD 32 Fire / Crane / Equipment Failure

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a crane-cab fire on WD 32 E on 25 March 2014. Worn electrical wiring sparked and ignited oil beneath the cab floor. The report examines unresolved inspection deficiencies, delayed critical repairs and the operator’s concerns about reporting defects, then records repair verification and successful safety-function tests before return to service.

Topics

About This Record
Original title
03-25-2014 22:00 00367 WD 32 Fire / Crane / Equipment Failure
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Electrical Safety, Fire, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Crane
Control
Fire Protection, Functional Testing, Pre-Use Checks
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-239452acb1 · added 2 October 2026