Vibration-induced fatigue on process pipework
Read at NOPSEMAOpens the document on nopsema.gov.au
Summary
This alert describes fatigue cracking in seawater cooling pipe connections and a hydrocarbon test separator header leak repaired without a major release. It calls for assessment of vibration excitation, points to Energy Institute pipework guidance and explains dangerous-occurrence reporting requirements, including damage to safety-critical equipment.