Safety Flash
Dropped object: Dislodged flex-joint laydown tool component
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An 85 kg load-ring half plate fell about 1.8 m to deck during flex-joint laydown-tool removal on a tilted J-Lay Tower. Nobody was injured. Manual removal replaced the approved crane-assisted method without risk assessment. The flash emphasises procedural compliance, management of change and stopping work when uncertain.