Main Crane failure during load test
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An offshore crane overload test ended with broken main-block wires and two cargo barges falling into the water. Uneven drum torque followed clutch-pad slipping, linked to inadequate burnishing of new pads. The vessel listed approximately nine degrees; nobody was injured. Lessons cover burnishing, torque testing, planned maintenance and crane FMEA review.