Safety Flash
Dropped object due to over-ridden limit switch
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A vessel crane operator bypassed limit switches while raising the hook for an overboarding lift. A mini beacon struck the clump weight and fell to the deck; a restraint and sensor cable also parted. Nobody was injured. The flash examines knuckle-boom configuration, override decisions, safety-system verification and safer equipment design.