NTSB: Fire on vessel – stray electrical current during welding
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
This safety flash summarises a fire aboard Qualifier 105 during aluminium welding in winter yard storage. The probable ignition source was electrical but undetermined; stray welding current remained unconfirmed. Combustible accommodation materials increased damage. The lesson recommends placing the welding return clamp as close as possible to the weld.