Safety Flash
BSEE: Overhaul Ball falls to deck resulting in High Potential near miss
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A safety flash describes a 350 kg crane headache ball falling 8 m during decommissioning and well abandonment, landing less than 60 cm from a rigger. A snag above the load cell masked slack developing during a blind lift. Recommendations address snag identification, slack detection, crew communication and lift planning.