Safety Flash
Three incidents of decompression illness (DCI)
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
Three divers experienced decompression illness during one project involving dives to 40 m in cold temperate waters. Investigation identified tight gloves and inadequate dry-suit undergarments. The flash recommends properly fitted, sufficiently insulating clothing and consideration of dive-profile restrictions or adjustments when appropriate clothing is unavailable.