Safety Flash
Pedestal Drill Chuck Assembly Detached Causing Head Injury
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A crewman suffered a forehead laceration when a benchtop drill’s chuck assembly was ejected in a vessel’s engine room. An unauthorised bolt substitution for the spindle sleeve, inadequate supervision and an unsafe work system were identified. Lessons address avoiding modified tools, inspecting equipment and removing unfit machinery from use.