Safety Flash
Sheave became detached during lifting operations
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A sheave detached during recovery of marine geophysical sensors and fell approximately 6 m to the deck, with nobody underneath. The flash identifies installation, change-management and verification shortcomings, including removed secondary retention. Actions included replacing the swivel connection, adding securing arrangements and improving equipment records and written instructions.