Safety Flash
Loss of redundancy in diving bell launch and recovery PLC system
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A diving bell launch and recovery system lost automatic PLC redundancy when a synchronisation module developed a faulty transmitting diode. Unavailable spares delayed repair. Following risk assessment and successful testing of independent processors and manual changeover, the vessel resumed work using temporary manual redundancy. Automatic redundancy was subsequently restored in port.