Safety Flash
IOGP: Dropped object with potential for injury – riser release
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
This flash describes premature anchor-tool release during recovery of a 16-inch riser from a jack-up drilling unit. The riser dropped approximately 14 metres, damaging the subsea wellhead sealing face without injuries. It reports pull-test and load-rating discrepancies and relays IOGP’s recommendation for continuous pressure energisation of the tool’s slip mechanism.