Safety Flash
Diver experienced an air flow restriction
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A surface-supplied diver experienced restricted air flow at 23msw and the dive was aborted without injury. Investigation identified a needle valve that failed to open properly, with possible overtightening linked to premature equipment fatigue. Actions included valve replacement, revised pre-dive checks and operating procedures, and a team emergency debrief.