Safety Flash
Worker hit by steel plate falling from crane
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A worker suffered severe back injuries when a steel sheet detached from a crane-mounted magnet during staircase construction. The HSE investigation identified inadequate lifting equipment strength and stability, a need to de-rate the magnet for the sheet’s dimensions, and failures in competent lift planning and supervision.