Safety Flash
Serious dropped object incidents
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
Two dropped-object incidents involved a hang-off module pad and a pipelay vessel tensioner guide. The first damaged access steps and unbalanced a technician; the second injured a rigger. Findings included corroded threads and sheared retaining bolts. Reported measures addressed lifting-bracket design, thread condition and corrosion protection.