Safety Flash
Failure of lifting equipment: Dropped ROV
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An offshore lifting incident involved a fibre sling failing and an ROV/TMS assembly dropping from 30 cm onto a vessel’s deck, damaging the ROV without injuries. Findings included unsuitable rigging, an unprotected sharp edge, absent supervision and no lift plan. Preventative actions address planning, supervision, certified equipment and sling protection.