Safety Flash
Main bell wire rope failed destructive test
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A diving support vessel’s main bell wire rope failed annual destructive testing after 245 bell runs. Investigation linked reduced load-bearing capacity to poor ductility from strain ageing and identified procurement outside company integrity arrangements. The flash calls for compliance with wire rope integrity requirements and oversight of chartered third-party vessels.