Safety Flash
Power management system dynamic positioning (DP) incident
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A power management fault interrupted stern thruster operation during saturation diving, causing a DP vessel to leave its intended position. Divers returned to the bell and were recovered. The flash examines inadequate control-card segregation and an unidentified single-point failure, recommending reconfiguration, electrical protection, independent review and FMEA validation trials.