Safety Flash
Objects dropped from pipelay tower
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
A shaft and end cap fell approximately 57 m from a pipelay tower four weeks after repairs, without injury. End-cap bolts had loosened after installation without thread locker. The flash identifies missing maintenance instructions and asset registration, and records improved fastener retention, integrity checks and scheduled maintenance.