Safety Flash
Crane whip line parted during hook stop testing
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
During auxiliary winch hook-stop testing, uncontrolled hoisting caused a headache ball to strike the crane jib, snap the wire and fall with the rigging to deck. Corroded speed encoders and poor wire condition were identified. The flash addresses rope examination, encoder maintenance, management of change and start-up risk assessment.