Safety Flash
Parting of a crane lift wire
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An 82.5 te riser anchor dropped to the seabed after a ship’s crane wire parted; nobody was injured. The investigation attributed the apparent failure to slack allowing the wire to overrun a sheave and bear on its pin. Actions included retention checks, improved operator visibility and conditional sheave observation before lifting.