Safety Flash
Umbilical support frame made contact with passing vehicle on public road
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
An umbilical support frame wing dropped during public-road transport and struck a passing vehicle. The flash identifies missing transport brackets, assumptions about retaining pins and absent securing instructions. Actions address drawing conformity, equipment marking, mobilisation and de-mobilisation verification, planning meetings and clear instructions for those moving specialist equipment.