Safety Flash
High potential dropped object
Read at IMCAOpens the publisher’s page on imca-int.com
Summary
During vessel pipe spooling, a 60 kg Hilman roller chain fell 10 m after a link plate failed. No injuries occurred, but a detached 2 kg roller landed outside the barriers. The flash discusses secondary retention, thorough pre-use inspections, dropped-object sweeps and barrier positioning that accounts for rebounds. The failure’s cause remained unidentified.