Safety Alert
Hand-Held Angle Grinder Injury
Read at IADCOpens the publisher’s page on iadc.org
Summary
A rig welder modifying a rotary guard was dressing a weld with a hand-held angle grinder when its wheel shattered. A fragment struck his left leg below the knee, causing a two-inch cut requiring six stitches. The injury was classified as a restricted-work case.