Investigation Report

Equinor – Troll C – investigation of incident with gas cooler cracks

HavtilNorwegian Ocean Industry Authority

Equinor – Troll C – investigation of incident with gas cooler cracks

Read at HavtilOpens the document on havtil.no

Summary

The PSA investigates externally initiated chloride stress corrosion cracking in Troll C’s second-stage gas coolers. Through-wall cracks compromised pressure containment, with potential for a major gas leak. Findings address coating inspection, preventive maintenance, consequence classification and passive fire protection. Penetrant testing revealed shell cracking; no harm to people or the environment was identified.

Topics

About This Record
Publisher
Norwegian Ocean Industry Authority
Type
Investigation Report
Date
Unknown
Topic
Corrosion, Loss of Containment, Pressure Systems, Structural and Asset Integrity
Activity
Inspection and Maintenance
Equipment
Pressure Vessel
Control
Fire Protection, Non-Destructive Testing, Preventive Maintenance
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
havtil-4be92ccf43 · added 2 October 2026

Report a problem with this record