Investigation Report

Valve Assembly Falls During Preparations for Blowout Preventer Testing

BSEEBureau of Safety and Environmental Enforcement

04-17-2007 02:00 G27483 BA/A24 LTA (>3 days) - Drill Pipe/Valve Back Out

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a valve assembly falling during preparations for blowout preventer testing. An escaping worker slipped and suffered a severe left-arm injury. The report identifies a backed-out drill-pipe connection and discusses how pipe-spinner positioning could loosen upper connections before the assembly received its required torque.

Topics

About This Record
Original title
04-17-2007 02:00 G27483 BA/A24 LTA (>3 days) - Drill Pipe/Valve Back Out
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Dropped Objects, Mechanical Failure, Slips, Trips and Falls
Activity
Drilling, Lifting Operations
Equipment
Rotating Machinery, Valve
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-fa22c47395 · added 2 October 2026