Investigation Report

Platform Flash Fire Following Gas Blow-By Through Separator Dump Controller

BSEEBureau of Safety and Environmental Enforcement

06-18-2005 23:15 G02047 EC/272 Fire - Explosion

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a production-platform flash fire following gas blow-by through a malfunctioning high-pressure separator dump controller. Gas reached the oil stock tank and escaped through secondary vents, accumulating near the generator building. Findings address building isolation, overlooked warnings, operator familiarity, supervision and failure to use stop-work authority.

Topics

About This Record
Original title
06-18-2005 23:15 G02047 EC/272 Fire - Explosion
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Hydrocarbon Release, Mechanical Failure, Process Safety
Equipment
Pressure Vessel, Storage Tanks
Control
Competence and Training, Operational Supervision, Pressure Relief, Stop-Work Authority