Investigation Report

Hot Sewage Burns During Marine Sanitation Pump Troubleshooting

BSEEBureau of Safety and Environmental Enforcement

11-07-2015 21:00 G15607 GC 743 LTA (>3 days) / Required Evacuation/ Other Injury/ Equipment Failure/ Human Error

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of burns sustained while troubleshooting a marine sanitation pump aboard Seadrill West Auriga. Scale blocked discharge piping, causing overpressure and sight-glass failure that released hot sewage. Findings address absent overpressure protection, hazardous viewing position and missing troubleshooting procedures. Medical evacuation was delayed by weather.

Topics

About This Record
Original title
11-07-2015 21:00 G15607 GC 743 LTA (>3 days) / Required Evacuation/ Other Injury/ Equipment Failure/ Human Error
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Line of Fire, Loss of Containment, Mechanical Failure, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines, Pumps
Control
Operating and Work Procedures, Pressure Relief
Sector
Upstream Oil and Gas
Setting
Vessel