Explosion During Flange Opening to Install a Skillet

BSEEBureau of Safety and Environmental Enforcement

06-24-2022 1147 G04782 MP 260 P Explosion - required evacuation

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates an explosion during flange opening to install a skillet on Main Pass 260 Platform P. Two workers received medical evaluation and returned to unrestricted duty that day. No root cause was identified; pyrophoric iron was considered the most likely explanation, with inadequate hazard analysis and absent pipe purging or flushing highlighted.

Topics

About This Record
Original title
06-24-2022 1147 G04782 MP 260 P Explosion - required evacuation
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Explosion, Hazardous Substances, Human Factors
Equipment
Process Pipework and Pipelines
Control
Ignition Source Control, Energy and Process Isolation, Risk Assessment
Sector
Construction
Setting
Offshore Installation