Investigation Report

Crane Boom Cable Failed and Struck Flagman During Casing Cutting

BSEEBureau of Safety and Environmental Enforcement

01-06-2008 07:45 G03323 EC/220 Other Injury - Crane

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a crane boom cable failure during well abandonment and casing cutting. A falling cable bruised a flagman’s left bicep. Findings address worn and rusted cable, a seized sheave, unreliable load indication, overloading and missing inspections. Recommendations cover defective equipment withdrawal, maintenance intervals and daily operational checks.

Topics

About This Record
Original title
01-06-2008 07:45 G03323 EC/220 Other Injury - Crane
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Corrosion, Line of Fire, Mechanical Failure
Activity
Inspection and Maintenance, Lifting Operations, Well Abandonment
Equipment
Crane, Wire Rope
Control
Functional Testing, Pre-Use Checks, Preventive Maintenance
Sector
Upstream Oil and Gas