Investigation Report

Pressurised Piping Strikes Operator During Gas Generator Starter Troubleshooting

BSEEBureau of Safety and Environmental Enforcement

11-01-2011 15:13 G12808 WC/616 LTA (>3 days) - Other

Read at BSEEOpens the document on bsee.gov

Summary

An investigation examines a contract lead operator’s fractured ribs during gas-generator starter troubleshooting. After a union was disconnected, opening the Amot valve released pressure that made the piping rotate and strike him. Findings identify omitted job safety analysis, failure to follow hazardous-energy controls and an unused pressure-checking arrangement.

Topics

About This Record
Original title
11-01-2011 15:13 G12808 WC/616 LTA (>3 days) - Other
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Line of Fire, Pressure Systems
Activity
Inspection and Maintenance
Equipment
Process Pipework and Pipelines, Valve
Control
Job Safety Analysis, Lockout and Tagout
Link
Checked , working
Record
bsee-c3ea5a9f05 · added 2 October 2026