Safety Alert 3 - Flash Fire, Glycol Gas Dehydrator Unit
Safety Alert 3 - Flash Fire, Glycol Gas Dehydrator Unit
- BSEE
- Safety Alert
- BSEE Safety Alert 3
- FireHydrocarbon releaseMaterial fatigue
- Inspection and maintenance
- Process pipework and pipelines
- Ignition source controlPreventive maintenance
- Upstream oil and gas
- Offshore installation
Summary
A gas production platform flash fire followed a fatigue crack in threaded glycol return pipework. Released gas and condensate ignited on an uninsulated reboiler stack. Vibration was identified as the probable fatigue cause. Recommendations address vibration damping, periodic pipework inspections and insulation or double-wall exhaust stacks at potential ignition sources.
Classifications: Fire; fire safety.
Classifications: Hydrocarbon release; hydrocarbon leak; oil and gas release.
Classifications: Material fatigue; metal fatigue.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Process pipework and pipelines; process piping.
Classifications: Ignition source control; ignition prevention.
Classifications: Preventive maintenance; preventative maintenance; planned maintenance.
Classifications: Upstream oil and gas; oil and gas extraction; upstream petroleum.
Classifications: Offshore installation; offshore platform; offshore rig.
BSEE Safety Alert 3.