Rigger Trapped Between Rolling Muffler and Scaffold During Valve Lifting
08-06-2013 19:25 00031 GI 22 L Required Evacuation / RW/JT (>3 days)
- BSEE
- Investigation Report
- Unknown
- Crushing and pinch pointsHuman factorsStructural and asset integrity
- Inspection and maintenanceLifting operations
- Crane
- Positive retention and reliable securing
- Construction
Summary
Investigation of a rigger trapped between a rolling muffler and scaffold during butterfly-valve lifting. The report identifies inattention, pinch-point exposure, insufficient mounting bolts and slip bracing, with vessel movement a possible contributor. The blind lift used radio communications and signalmen; the worker sustained a hairline shoulder-blade fracture.
Classifications: Crushing and pinch points; crush hazards; pinch points.
Classifications: Human factors; human performance; ergonomics.
Classifications: Structural and asset integrity; asset integrity; structural integrity.
Classifications: Inspection and maintenance; asset inspection; equipment maintenance.
Classifications: Lifting operations; load lifting; hoisting.
Classifications: Crane; cranes.
Classifications: Positive retention and reliable securing.
Classifications: Construction; construction industry.