Investigation Report

Rigger Trapped Between Rolling Muffler and Scaffold During Valve Lifting

BSEEBureau of Safety and Environmental Enforcement

08-06-2013 19:25 00031 GI 22 L Required Evacuation / RW/JT (>3 days)

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a rigger trapped between a rolling muffler and scaffold during butterfly-valve lifting. The report identifies inattention, pinch-point exposure, insufficient mounting bolts and slip bracing, with vessel movement a possible contributor. The blind lift used radio communications and signalmen; the worker sustained a hairline shoulder-blade fracture.

Topics

About This Record
Original title
08-06-2013 19:25 00031 GI 22 L Required Evacuation / RW/JT (>3 days)
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Crushing and Pinch Points, Human Factors, Structural and Asset Integrity
Activity
Inspection and Maintenance, Lifting Operations
Equipment
Crane
Control
Positive Retention and Reliable Securing
Sector
Construction
Link
Checked , working
Record
bsee-a740895227 · added 2 October 2026