Investigation Report

Bridge-Plug Assembly Falls During Temporary Well Abandonment and Injures Worker

BSEEBureau of Safety and Environmental Enforcement

08-30-2011 16:30 00247 WC/102 Required Evacuation - RW.JT (1-2 days) - Other

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of an electric-line wire-rope failure during temporary well abandonment at Apache WC 102-2. A bridge-plug assembly fell and injured a worker’s foot. Laboratory examinations confirmed corrosion-related shear/overload fractures. Findings address departure from the approved workstring method, incomplete job safety analysis and missing maintenance records.

Topics

About This Record
Original title
08-30-2011 16:30 00247 WC/102 Required Evacuation - RW.JT (1-2 days) - Other
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Corrosion, Dropped Objects, Mechanical Failure
Activity
Lifting Operations, Well Abandonment
Equipment
Wire Rope
Control
Job Safety Analysis, Operating and Work Procedures, Preventive Maintenance
Sector
Upstream Oil and Gas
Link
Checked , working
Record
bsee-a0ede35dde · added 2 October 2026

Report a problem with this record