Summary

Investigation of two related December 2017 incidents on the Constitution spar involving descent of a dry tree and riser. Corroded buoyancy-can air lines allowed nitrogen escape and seawater entry, reducing support and overloading deck grating. The report describes shutdowns, mustering, ROV damage assessment and inspections of similar systems.