Investigation Report

Compressor Piston Failure and Fire with Shutdown System Failure

BSEEBureau of Safety and Environmental Enforcement

01-16-2024 0252 G02587 SM 128 B Fire, Incident > $25K, Damaged/Disabled Safety System

Read at BSEEOpens the document on bsee.gov

Summary

BSEE investigates a compressor piston failure and fire at South Marsh Island 128 B. Operators extinguished the fire without injuries. The vibration switch tripped but failed to initiate shutdown; frozen condensation was suspected. The report records switch testing and desiccant dryers ordered for the pneumatic control supply.

Topics

About This Record
Original title
01-16-2024 0252 G02587 SM 128 B Fire, Incident > $25K, Damaged/Disabled Safety System
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Functional Safety, Mechanical Failure
Activity
Inspection and Maintenance
Equipment
Rotating Machinery
Control
Emergency Response, Fire Protection, Functional Testing
Sector
Upstream Oil and Gas
Setting
Offshore Installation
Link
Checked , working
Record
bsee-55f1d7fba3 · added 2 October 2026