Investigation Report

LACT Charge-Pump Fire Following Motor-Bearing Failure

BSEEBureau of Safety and Environmental Enforcement

07-09-2006 01:45 P00315 SM6525 Fire - <$25K

Read at BSEEOpens the document on bsee.gov

Summary

Investigation of a LACT charge-pump fire examines catastrophic motor-bearing failure, axial loading and likely ignition of barrier fluid. Deluge contained the flames, with residual fire extinguished manually. Approximately ten gallons of crude oil remained within the deck drainage system. Proposed measures address pump selection, thrust bearings, barrier fluid and increased monitoring.

Topics

About This Record
Original title
07-09-2006 01:45 P00315 SM6525 Fire - <$25K
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Fire, Hydrocarbon Release, Mechanical Failure
Equipment
Pumps, Rotating Machinery
Control
Fire Protection
Sector
Upstream Oil and Gas
Link
Checked , working