Summary

An investigation records hydraulic-fluid pollution following a BOP control-computer switch that generated a spurious release signal and activated riser-tensioner valves. Venting went unnoticed for seven hours; 250 gallons entered the sea. The LMRP remained connected. Measures included temporary recoil-system isolation, proposed closed-loop recovery, software corrections and requested alarm-priority changes.

Topics

About This Record
Original title
08-17-2006 02:00 G08035 AT/574 Pollution
Publisher
Bureau of Safety and Environmental Enforcement
Type
Investigation Report
Date
Unknown
Topic
Environmental Protection
Activity
Drilling
Equipment
Blowout Preventer, Operator Displays and Control Interfaces, Valve
Control
Alarm Management, Energy and Process Isolation
Sector
Upstream Oil and Gas
Setting
Marine Waters
Link
Checked , working
Record
bsee-41a77f3791 · added 2 October 2026