Investigation Report
Casing Joint Dropped During Electromagnetic Pipe Handler Transfer
Read at BSEEOpens the document on bsee.gov
Summary
An investigation examines a casing joint dropped during transfer by an electromagnetic pipe handler on Cajun Express. Contact with a riser tensioner dislodged the load from its magnets. Findings identify incorrect alignment, unsuitable spotter positioning and absent discussion of spotter responsibilities. No injuries occurred; casing threads were damaged.